Troubleshooting
If SpanDraft does not calculate a result or a result looks unexpected, most causes can be narrowed down by checking the supports, loads, geometry, units, and model limitations.
No results
| Situation | Check |
|---|---|
| Calculation unavailable · Supports missing | Add the required supports. |
| Calculation unavailable · Insufficient support | Are all rigid-body movements restrained? |
| Calculation unavailable · Incomplete model | Check the reported inputs. |
| Calculation not possible | Check the geometry and unusual ratios between dimensions. Numerically problematic models may cause the calculation to stop. |
| A change has not yet been applied | Confirm the input. |
A common case is a beam with two Roller Supports at different positions. They prevent vertical rigid-body motion but leave the entire beam free to move axially.
A typical simple support arrangement therefore uses a Pinned Support together with a Roller Support. See Supports and boundary conditions.
Input is not applied
SpanDraft applies only inputs from which a valid model can be created. The specific error message normally indicates which value must be corrected.
Typical invalid inputs
- Position outside
0 ≤ x ≤ L. - Distributed load without a valid range
xStart < xEnd. - Two supports at the same position.
- Shortening the beam would leave existing loads or supports outside the beam.
- Geometrically invalid cross-section.
- Invalid material values: properties must remain within the physical ranges accepted by SpanDraft.
- Duplicate name.
Self-weight cannot be enabled
Self-weight requires a density for the selected material. If no density is available, SpanDraft displays:
Self-weight cannot be included. No density is specified for the material.
The name g is reserved for self-weight. If an existing support or load already uses g or G, rename that entity before enabling self-weight.
A result looks implausible
Check the model in this order:
- Loads: Are the magnitude, direction, position, and loaded region correct?
- Supports: Does the idealized support arrangement represent the real situation?
- Beam and cross-section: Are the beam length, cross-section dimensions, and bending axis correct?
- Material and units: Are the material properties and selected display units plausible?
- Model limitations: Does the problem fit the two-dimensional SpanDraft beam model?
If necessary, a simple reference load case or an independent equilibrium check can provide an additional plausibility check.
An example is shown under First calculation.
The results are explained under Result diagrams and support reactions and Bending stress and safety factor.
Very small nonzero values remain visible. With automatic engineering notation, they may be displayed using a power of ten. The calculation continues to use the unrounded value.
Problems with project or library files
- Projects store their material and cross-section data independently of the libraries.
- Damaged files are not repaired automatically.
If a project file is damaged, use an intact backup whenever possible.
Recovery after a crash
After an unexpected shutdown, SpanDraft may offer to restore a local unsaved editing state.
The original project file is not overwritten automatically. Review the restored state and then save it deliberately.
Technical background: Stations and equation system; Numerical solution and accuracy.